Connecting broadband™ radar – B&G Zeus 12 User Manual

Page 34

Advertising
background image

Wiring the Zeus Display

| 33

Connecting BroadBand™ Radar

+_

B

C

D

E

F

F

G

G

I

J

H

H

A

Power

Scanner cable

SimNet

Network

Brown RX-

White RX+

AT10HD

NMEA0183 to SimNet

Converter Heading Only

Cut off 12 Pin

plug to expose bare wires

NMEA0183 10 Hz Heading

(e.g Gyro, Sat Compass)

Alternative: NMEA0183 heading

TX-

TX+

Key

Description

A

Zeus Display.

B

BroadBand™ Radar system for Zeus. Includes parts C,D and E.

C

Scanner cable. 20 m (65 ft) : Optional 10 m (33 ft) and 30 m (98 ft).

D

RI10 Radar interface box.

E

Ethernet cable. BroadBand™ Radar comes with a 2 m (6.5 ft) 5 pin cable. The

RI10 can be connected directly to Zeus or via a Network Expansion Port. See

Ethernet cables yellow for more cable length options.

F

SimNet Drop Cables: The BroadBand™ Radar and Zeus are connected to

the SimNet backbone BroadBand™ Radar uses heading at 10 hz to calculate

MARPA. (Not included)

G

Power cable. (see Power section). Always use a fuse or breaker.

H

SimNet backbone. Refer to SimNet section.

I

Power control bus: In this case BroadBand™ Radar is connected to Power

Control Bus. BroadBand™ Radar is turned on when the Zeus is powered on.

J

For MARPA and chart overlay use a heading sensor.
Either a SimNet / NMEA2000 heading sensor such as the GRC3. Or if a

NMEA0183 10 hz heading sensor is installed, convert to SimNet using a AT10HD

or connect to the NMEA in port on a Zeus. Refer NMEA0183 Wiring.

Advertising