Radar setup – B&G Zeus 12 User Manual

Page 41

Advertising
background image

40 | Commission the System

Water Speed Averaging

Averages water speed by measuring your speed at a selected interval of time. Water

speed intervals range from one to thirty seconds. If you select five seconds, your water

speed will be recorded every five seconds, then averaged.

Calibration range: 1-30 seconds. Default is 1 second.

Temperature Calibration

Temperature calibration is used to adjust the water temperature value from the echo

sounder transducer to match the data from another temperature sensor.

Calibration range: -9.9° - +9.9°. Default is 0°.

Transducer Type

Transducer type is used for selecting the transducer model connected to the echo

sounder module. In some transducers with built-in temperature sensors, the

temperature may not be correct if the correct transducer is not selected from the

transducer type menu.

See compatible transducer list

Note: Other depth sources will have their own calibration

Radar setup

Basic set up is required on all new radar installations. The set up varies slightly between

Boradband radar and the range of conventional HD pulse radars. The Zeus will detect the

type of radar and display relevant information.

Broadband Radar™

HD Pulse Radar

To commission a

BroadBand™ Radar:

set bearing

alignment

set antenna

height

local interference

rejection (if

needed)

To commission a

pulse radar;

set bearing

alignment

set antenna

height.

set range offset

Park angle for

open array

scanners

HD Pulse Radars: Leave in standby for 30 min before transmitting. (First time only) to

burn in the magnetron.

Radar Software Version

Radar type and software version are displayed under radar installation. To upgrade radar

software refer to Software Upgrades.