METHOD 2. - MANUAL CALIBRATION - LOG CAL


If the log or boat speed is in error by a known percentage
then this method allows the calibration figure or LOG CAL to
be adjusted by that amount. The calibration figure is
measured in Hertz per knot (Hz/kt), the factory set value is
6.25.

NOTE
: The accuracy of this method is dependant upon the
accuracy of the calculated percentage error.

Using the factory set LOG CAL of 6.25 Hz/kt:

• If the display is under reading by 10% subtract 0.62

• If the display is over reading by 10% add 0.62

Press SPEED key
to display current
boat speed.

Press SETUP key
four times to
display LOG
CAL
.

Press ENTER key
to adjust the
displayed value.

Use

S or T to

change the value.

Press ENTER to
store the new
value in memory.

Press SPEED key
to complete
change.