Read and understand steps 8–11 fully
before proceeding. These steps are time
sensitive!

8. Using the DPTP labeled “C”, pipet 500 µl

of buffer into the 15 ml conical tube
labeled “Control” and gently mix. Once
you have mixed the buffer with the
substrate, remove 500 µl of this solution
and add it to your cuvette labeled “Start”.

9. Using the DPTP labeled “E”, pipet 1 ml of

enzyme into the 15 ml conical tube
labeled “Enzyme Reaction”. Gently mix,
then START YOUR TIMER.

10. At the times indicated, use the DPTP

labeled “E” to remove 500 µl of the
solution from the “Enzyme Reaction”
tube and add it to the appropriately
labeled cuvette containing the stop
solution.

11. After all the enzyme samples have been

collected, use the DPTP labeled “C” to
remove 500 µl of the solution from the
“Control” reaction tube and add it to the
cuvette labeled “End”.

12. Proceed with the analysis of your

samples. After you have finished your
analysis, rinse out your reaction (conical)
tubes, cuvettes, and DPTPs with copious
water and save them for later activities.

Note: Do not discard unused stock solutions.
They will be used for the next activity.

27

Quick Guide

Q

UICK GUIDE

Enzyme
reaction

E1

1 min

E2

2 min

E3

4 min

E4

6 min

E5

8 min

Control

End

8 min

Buffer

Control

Enzyme

Enzyme reaction

Control

Start