2 (4.2) op wdt stats, 3 (4.3) op wdt reset, 2) op wdt stats – Colorlight CL20 User Manual

Page 40: 3) op wdt reset

Advertising
background image

Page 40

INSTALLATION MANUAL CL20

16.5.2 (4.2) OP WDT Stats

Displays a counter that keeps track of the number of times the Ethernet communication has
been recovered from an OP WDT event.
In case of suspected cable problems with connected operator panels, this counter can be
helpful when troubleshooting.

16.5.3 (4.3) OP WDT Reset

Resets the OP WDT counter.
A confirmation message, “If sure press OK”, is displayed upon entering the menu. Press the
OK” button at this point to reset the counter and exit the menu. Press the “Down” or “Right
button to exit the menu without resetting the counter.