INSTALLATION MANUAL CL25, CL35

Ethernet wiring

8.6


ColorLight searchlight systems should be connected to their own dedicated network; they
should never be connected into the vessels existing computer network.

An Ethernet cable supplied by ColorLight complies with the standard TIA/EIA-568-B and is
always tested together with the complete searchlight system to ensure full functionality.

If customers choose to assemble their own Ethernet cables they must be of type FPT Cat5 or
better and the connections should be done according to the following information.


Note that the only difference between T568A and T568B is that pairs 2 and 3 (orange and
green) are swapped. Both configurations wire the pins "straight through", i.e., pins 1 through 8
on one end are connected to pins 1 through 8 on the other end. Also, the same sets of pins
connect to the opposite ends that are paired in both configurations: pins 1 and 2 form a pair, as
do 3 and 6, 4 and 5, and 7 and 8.
One can use cables wired according to either configuration in the same installation without
significant problem. The primary thing one has to be careful of, is not to accidentally wire the
ends of the same cable according to different configurations

Pin

T568A

Pair

T568B

Pair

T568A

Color

T568B

Color

Pins on plug face

1

3

2


white/green
stripe

white/orang
e stripe

2

3

2

green solid

orange solid

3

2

3

white/orang
e stripe

white/green
stripe

4

1

1

blue solid

blue solid

5

1

1

white/blue
stripe

white/blue
stripe

6

2

3

orange solid green solid

7

4

4

white/brown
stripe

white/brown
stripe

8

4

4

brown solid

brown solid

1