Switch on light, Switch on light 14 – Colorlight CL25 Installation manual User Manual

Page 33

Advertising
background image

INSTALLATION MANUAL CL25, CL35

Page 33

SWITCH ON LIGHT

14.


The searchlight is equipped with two bulbs with either double white (CLXX-11) or double UV
(CLXX-22) or a combination of white and UV light.
As default the double white or double UV will be turned on by pressing button(2) or (5), both
lights will then be lit with a slight delay in between, no matter which button is used.
To turn off the light, press button (2) or (5) again.

There are however occasions when it may be useful to give each bulb a dedicated light button,
this setting is done in the "Single lamp mode" menu, please see

User’s Manual, section

11.8.6.5

Single lamp mode.


If the light is a combination of white/UV, light will always be lit separately. Button (2) will lit left
light and button (5) the right light. To turn off light, press the same button again.
In the bottom part of the display there are two sun-symbols that indicates the status of each
bulb.

CL25 and CL35

If the system is unable to switch on the bulbs there will be a red exclamation mark over the sun-
symbol for the no working bulb. This error might occur if the operator decides to switch on a
bulb that recently has been shut off without any time to cool down before the next switch on.
Normally wait a few seconds (the longer the better) and try again. The system accepts three
turn on attempts (initiated by the operator) in a two minute time interval before the sum-alarm is
activated.

If the bulb breaks during operation the sum-alarm will be activated directly. The error symbol
with the exclamation mark over the sun-symbol will show again in the display over the
corresponding bulb.

There is a bulb warning feature in the system. This warning can be chosen by the operator to be
shown or not by switch on or off the function in the settings menu, please see

User’s Manual,

section

11.8.4 Lamp life.


This warning feature will show a white triangle symbol when the estimated bulblife left is
less than 200 hours. The symbol will be shown at the displays bottom left or right corner
according to left or right bulb.


When the expected lifetime is expired the white triangle will change to a red triangle.
The only way to reset this symbol is by entering the “lamp life” menu at the diagnostic
display inside the electrical box. To get to the correct menu use the three buttons below

the display. Under the lamp life menu there are two choices: “usage statistics” and “reset
counters

”. Select “reset counters” and select the corresponding lamp housing for which the

counter should be reset. Certainly this reset should only be done together with a bulb
replacement!