1 ebox alarm relay, Ebox alarm relay, Ebox alarm relay 10.1 – Colorlight CL25 Installation manual User Manual

Page 29

Advertising
background image

INSTALLATION MANUAL CL25, CL35

Page 29

This symbol indicates that the bulb has less than 200 hours left of expected
lifetime. This warning can be chosen by the operator to be shown or not.

please

see

User’s Manual,

11.8.4 Lamp life

for more detailed instruction.

Each bulb has its own symbol showing in the lower left or right corner of the
display.



This symbol indicates that the expected lifetime of the bulb now has expired. The
only way to reset this symbol is by entering the “Usage Stats” menu at the
diagnostic display inside the electrical box. See

16.4 Category 3: Usage Stats

.

Certainly this reset should only be done together with a bulb replacement!



This symbol and a similar symbol indicate the direction of the lamp housing both

for the vertical axis and for the horizontal axis. The arrows in the shown symbol
indicate the elevation angle for the vertical axis according to the horizontal-plane.

For the horizontal symbol and axis these small arrows indicate if the housing is
directed to the left, front, right or back of the centerline.

If the arrows are replaced by question marks then the system needs to be
internally calibrated. This is the normal state after power up after a total power loss
to the system. The easiest way to do the internal calibration is by simply choose
the “Park” in the quick start menu, please see User’s Manual

10.6 Off and park.


Ebox alarm relay

10.1


The searchlights electrical and mechanical condition are constantly monitored
and if there is a malfunction in the system this is indicated by icons in the panel
display with clarifying warning messages found in the panels status menu.
The control box also has a relay output that can be connected to the boat
monitoring system; see the wiring diagram for connection details.

The following errors trigger the alarm output.

Message

Fault

Communication error

Transmission issues on the CAN bus

Over current

Overcurrent protection triggered, movement blocked

Over voltage

Overvoltage protection triggered, voltage to searchlight motordriver/s
have exceeded 30Vdc.

Under voltage

Undervoltage protection triggered,

voltage to searchlight

motordriver/s has fallen below 10Vdc

OPWDT (message in box only)

Ethernet communication broken to all panels, see

(4.1) OP WDT

.

Fault auto-resets if contact is restored with at least one panel