Motor holding torque on / off „db“ (44h, 42h) – Baumer N 152 User Manual

Page 10

Advertising
background image

N 152

www.baumer.com

10

Motor holding torque on / off „DB“ (44h, 42h)

Prior to utilizing “DB” command to activate / deactivate the holding torque it must be enabled first in command
„m“ since otherwise command „DB“ remains ineffective.
Holding torque ever ON means that only motive shaft positioning operations are possible - either by aid of the
two keys provided or by a corresponding command via interface. The holding torque is automatically deactivated
as soon as the motor is getting a start command and is later autonomously re-enabled. Manual positioning
operations by hand cranks etc require deactivating the holding torque first by command “DB”.

Following modes are available::

Status

Function

0 (30h) holding torque off
1 (31h) holding torque on


Example 1: Read current status (status = 0: no holding torque)

SOH Adr Cmd

SCmd

EOT CRC

Transmission

01h 20h 44h

42h 04h 80h

SOH Adr Cmd

SCmd

Stat. EOT CRC

Response

01h 20h 44h

42h 30h 04h 6Dh


Example 2: holding torque off (status = 0: unblock holding torque)

SOH Adr Cmd

SCmd

Stat. EOT CRC

Transmission

01h 20h 44h

42h 30h 04h 6Dh

SOH Adr Cmd

SCmd

Stat. EOT CRC

Response

01h 20h 44h

42h 30h 04h 6Dh


Example 3: holding torque off for all motors by broadcast command (ID=99)

SOH Adr Cmd

SCmd

Stat. EOT CRC

Transmission

01h 83h 44h

42h 30h 04h

57h

Response

not confirmed


Note: If the holding torque is enabled (command „m“) the clamping is always active upon power on, reason why
holding torque OFF by command „DB0“ is only effective whilst device is under power supply.