Read / write measuring unit „i“ (69h) – Baumer N 152 User Manual

Page 21

Advertising
background image

N 152

www.baumer.com

21

SOH Adr Cmd

MIN limit position = 0015.00

MAX limit position = 0850.25

EOT CRC

Response

01h 20h 67h

30h 30h 31h 35h

30h 30h 30h 38h 35h 30h

32h 35h 04h 1Fh


Example 2: Write limit positions (MIN = -33.22; MAX = 1234.56)

SOH Adr Cmd

MIN limit position = -033.22

MAX limit position = 1234.56

EOT CRC

Transmission

01h 20h 67h 2Dh 30h 33h 33h 32h 32h 31h 32h 33h 34h 35h 36h 04h 92h

Response

SOH Adr Cmd

MIN limit position = -033.22

MAX limit position = 1234.56

EOT CRC

01h 20h 67h 2Dh 30h 33h 33h 32h 32h 31h 32h 33h 34h 35h 36h 04h 92h

4.3.6. Read / write motor speed switching points „h“ (68h)

This command is utilized to read or write the motor speed switching points. Prior to reaching the target the motor
speed can be slowed down by two optional speeds (slow and precision) for absolutely precise positioning to the
target. The motor’s switchoff point might also be set to a certain value prior to reaching the target. The following
3 parameters are available:

Slow speed:

point where SPA changes from high speed to slow speed.

Precision speed: point where SPA changes from slow speed to precision speed.
Switchoff point: Position where motor is stopped by SPA .

The individual switching points are indicated in relation to the target.

Example 1: Read parameter (slow speed = 2.00; precision speed = 0.70; switchoff point= 0.02)

SOH Adr Cmd EOT CRC

Transmisison

01h 20h 68h

04h 5Ch

SOH Adr Cmd

Slow speed =2.00

Precision speed =0.70

Switchoff point =0.00 EOT CRC

Response

01h 20h 68h

30h 32h 30h 30h

30h 30h 37h 30h 30h 30h

30h 30h 04h 72h


Example 2: Wirte parameter (slow speed = 1.25; precision speed = 0.50; switchoff point = 0.01)

SOH Adr Cmd

Slow speed =1.25

Precision speed =0.50

Switchoff point =0.01 EOT CRC

Transmission

01h 20h 68h

30h 31h 32h 35h

30h 30h 35h 30h 30h 30h

30h 31h 04h EAh

SOH Adr Cmd

Slow speed =2.00

Precision speed =0.50

Switchoff point =0.01 EOT CRC

Response

01h 20h 68h

30h 31h 32h 35h

30h 30h 35h 30h 30h 30h

30h 31h 04h EAh

4.3.7. Read / write measuring unit „i“ (69h)

The command is for utilized to read or write the measuring unit in mm or inches.

Data = 0 (30h) = mm

Data = 1 (31h) = inch


Example 1: Read parameter (setting = mm)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

69h

04h

5E

SOH

Adr

Cmd

Data

EOT

CRC

Response

01h

20h

69h

30h

04h

D0h


Example 2: Change measuring unit into inches

SOH

Adr

Cmd

Data

EOT

CRC

Transmisison

01h

20h

69h

31h

04h

D2

SOH

Adr

Cmd

Data

EOT

CRC

Response

01h

20h

69h

31h

04h

D2


Example 3: Write measuring unit mm in all SPAs by broadcast command (identifier=99)

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

83h

69h

30h

04h

CDh

Response

not confirmed

Important: Parameters are programmed in mm and auto-converted by SPA into inches upon displaying the
position values.

Advertising