Parameter commands – Baumer N 142 User Manual

Page 15

Advertising
background image

N 142

www.baumer.com

15

4.2.10. Readout any optional number sequence in the bottom line of display,
command „u“ (75h)

The command is for indicating a 6-digit number in the bottom line. The number is displayed without dot
respectively comma. Preceding zeroes as well as both direction arrows are suppressed. The upper line still
indicates the current target or number sequence.
The number sequence is displayed until any optional command except „t“, „u“ or „R“ is received by the interface.
The number will be retained after power failure.

Example: (number sequence = 123456)

SOH Adr Cmd

Number sequence = 123456

EOT CRC

Transmission

01h 20h 75h 31h 32h 33h 34h 35h 36h

04h BCh

SOH Adr Cmd

Number sequence = 123456

EOT CRC

Response

01h 20h 75h 31h 32h 33h 34h 35h 36h

04h BCh


Important:
Command “t” in conjunction with command “u” enables displaying a 12-digit number.
Both numbers are not saved in EEPROM.

4.3. Parameter commands

Command Amount of data

in Bytes

read

write

Broad-

cast

Saved in

EEPROM

Significance

a (61h)

5

X

X

-

X

Read / write general parameters

b (62h)

8

X

X

-

X

Parameter: Tolerance compensation, window

c (63h)

8

X

X

-

X

Parameter: Scaling spindle pitch

g (67h)

12

X

X

-

X

Parameter: Limits MIN, MAX

h (68h)

12

X

X

-

X

Parameter: Switching points for motor speed.

i (69h)

1

X

X

X

X

Parameter: mm / inch

j (69h)

3

X

X

X

X

Parameter: Timeout for bus error

k (6Bh)

9

X

X

-

X

Parameter: Motor system cycles

l (6Ch)

5

X

X

-

X

Parameter: Jog

m (6Dh)

5

X

X

-

X

Read / write general parameters

x (78h)

5

X

X

-

X

Read / write specific parameters