6. Error warnings

Error warnings are visualized by a flashing upper display line, indicating alternately both error signal and current
value (usually target).

MAX limit of SPA hurt by manual positioning operation (by softkey)


Troubleshooting: Set SPA to the admissible positioning range.

MIN limit of SPA hurt by manual positioning operation (by softkey)


Troubleshooting: Set SPA to the admissible positioning range.

SPA is giving a motor start signal but N 142 hollow shaft does not move.


Troubleshooting: Check motor, cable and mechanical connections from motor to shaft to SPA.

Motor failure at SPA.
(Failure is indicated for approx 5 seconds if motor start is released by interface or
pushbutton)

Troubleshooting: Take corrective actions.

SPA did not reach the target window.


Troubleshooting: Extend the tolerance window. Set switchover to precision speed at an earlier

point.

Direction error. Shaft positioning is in the wrong direction.


Troubleshooting: Verify SPA parameterization ( for example motor direction of rotation, or motor

cable connection)

Target transmitted respectively DIM parameter is above the MAX limit.
Note: Consider any loops.

Troubleshooting: Transmit new valid position value.

Target transmitted respectively DIM parameter is below the MIN limit.
Note: Consider any loops.

Troubleshooting: Transmit new valid position value.