Germany

7 Disturbance

messages

If there occurred an error when turning power on or during parameterization, the encoder switches to the
DISTURBANCE state after the user has passed the device control command ENABLE OPERATION and allots a
disturbance number to the bits D25-D28 of the status word. If an error occurs within the encoder during the
OPERATION state (e.g.: disturbance number 15), the encoder automatically switches to the DISTURBANCE state.

Disturbance No.
D28 D25

Significance

0 0 0 0

No disturbance

0 0 0 1

Inadmissible parameter from Master

0 0 1 0

Unknown parameter number

0 0 1 1

Parameter loss

1 1 0 1

Error when storing into EEPROM

1 1 1 0

Warning: Battery tension too low

1 1 1 1

Faulty value of encoder disk



Status word at disturbance:

Status
word:

Actual posit.

vakue not

valid

Parameter-

izat

ion

specific to

manu-factorer

Disturbance no.

D31 D30 D29 D28 D27 D26 D25

Disturbanc
e

1

0

X

1...3 or 13...15



Sign a disturbance:

Status
word:

Enable

operation

Set zero

offset

specific to

manu-factorer

Disturbance no.

D31 D30 D29 D28 D27 D26 D25

Enable
operation

0>1

0 X

0