8 contact description – Baumer GXP6H User Manual

Page 11

Advertising
background image

Manual_GXP6H_EN.doc

11/13

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany

8 Contact

description

8.1 Contact description for C-plug


D01, D01

Incoming long-distance bus (A1) galvanically

DI1, DI1

separated from remaining encoder electr.


GNDI

Galvanically separated reference mass for incoming long-distance bus (A1).

Models without electrical isolation combined with GND.


UB

Contacts for encoder supply incorporated

GNDB

within the bus (A1), UB = 10...30 VDC. Current load max. 700 mA


D02, D02

Relaying long-distance bus (W1)

DI2, DI2

GND

Reference mass for relaying long-distance bus (W1)


UB

Contacts for encoder supply within bus

GNDB

(W1), UB = 10 ... 30 VDC. Connected internally with UB/GND B from A1


PE

Screening combined with encoder housing


RBST

Recognition of further bus users

Open contact: Last user

Contact to GND: User X


8.2 Pin assignment for C-plug

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9


Incoming interface

Outgoing interface

(pin)

(socket)


Pin

Assignment

Pin

Assignment

1 D01

1 D02

2 D01

2 D02

3 DI1

3 DI2

4 DI1

4 DI2

5 GNDI

5 GND

6 PE

6 PE

7 UB

7 UB

8 GNDB

8 GNDB

9 –

9 RBST

Advertising