Page 9

Matrix System and Control System Connection - RS-232

PC RS-232, multi-Matrix (up to 32) connections are as shown below.

NOTES:

1. For RS-232 connections refer to photo below.
2. RS-232 or RS-485 baud rates: 9600bps, 8-bit data transmission address, no, odd,

or even parity, 1-bit stop address: (9600 - 8 - N - 1).

3. Serial connection between Matrix RS-485 as follows:

TX (+)

↔ TX (+)

TX (-)

↔ TX (-)

RX (+)

↔ RX (+)

RX (-)

↔ RX (-)

4. DIP switch 1-5 addresses must not set to same ID address.






















(ID = 0)

(ID = 1)

(ID = 30)