40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS

(Models with Electric Ovens and Gas Cooktop)

Model and Serial Number Location

The serial plate is located on the oven front frame behind

the large oven door.
When ordering parts for or making inquiries about your

range, always be sure to include the model and serial

numbers and a lot number or letter from the serial plate

on your range (Figure 1).

Serial Plate Location

1.

Power Supply Cord Kit

The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring"; flexible armored or
nonmetallic shielded copper cable (when local code
allow it) or by means of a power supply cord kit.

Risk of fire or electrical shock exists

if an incorrect size range cord kit is used, the
Installation Instructions are not followed, or the
strain relief bracket is discarded.
For mobile homes, new installations or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 30A. Cord must have either 3
(when local code permits grounding through neutral) or
4 conductors. Terminal on end of wires must be either
closed loop or open spade lug with upturned ends. Cord
must have strain-relief clamp.

Do not loosen the nuts which secure

the factory-installed range wiring to terminal block
while connecting range. Electrical failure or loss of
electrical connection may occur.

NOTE: Range is shipped from factory with 1 1/8" dia. hole
as shown in figure 3. If a larger hole is required, punch out
the knockout.

2.

Access to Terminal Block &

Grounding Strap

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until

appliance is permanently grounded.

• Disconnect power to the circuit breaker or fuse

box before making the electrical connection.

• This appliance must be connected to a grounded,

metallic, permanent wiring system, or a
grounding connector should be connected to the
grounding terminal or wire lead on the appliance.

Failure to do any of the above could result in a

fire, personal injury or electrical shock.

Figure 2

Figure 1

To gain access to lower

terminal block bend lower

back cover plate along row

of holes shown here

Pressure

regulator location

This appliance is manufactured with

the frame grounded by connection of a grounding
strap between the neutral power supply terminal
and the frame. If used in USA, in a new branch
circuit installation (1996 NEC), mobile home or
recreational vehicule, where local code do not
permit grounding through neutral (white) wire
or in Canada; remove the grounding strap from
the frame and cut the other end, near the neutral
terminal. Connect the appliance in usual manner.