40" dual fuel range installation instructions, Models with electric ovens and gas cooktop), Junction box location – FRIGIDAIRE FPDF4085KF User Manual

Page 6: Range placement, Gas supply installation

Advertising
background image

6

40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS

(Models with Electric Ovens and Gas Cooktop)

Follow instructions for

the type of installation you have

Center

Line of

Range

Locate Electrical Hook-up

Inside Shaded Area

Center

Line of

Range

10"

(25.4 cm)

10"

(25.4 cm)

7" Max.

(17.8 cm Max.)

20"

(50.8 cm)

FLOOR

WALL

Center

Line of

Range

Figure 8

Junction Box Location

Locate junction box as shown in Figure 7.
If a service cord is used, the wall receptacle should be
located in accordance with the dimensions below.

Range Placement

To eliminate the risk of burns or fire by

reaching over heated surface units, cabinet storage space
located above the range should be avoided. If cabinet
storage space is to be provided, the risk can be reduced
by installing a range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the
cabinet.

Figure 7

If range will be installed with a cabinet on both

sides, draw a center line on the floor between the

cabinets (see figure 8). If back of range will not be

flush with the wall (the location of the outlet may not

allow the range to be positioned against the wall), draw

a line on the floor where the back edge of the range will

be. Now install anti-tip brackets (see "Anti-Tip Bracket

Installation, page 10).
If range will be installed with a cabinet on one side

only, move the range into final position. Draw a line on

the floor along the side of the range that is not against

the cabinet. If back of range will not be flush with

the wall (the location of the outlet may not allow the

range to be positioned against the wall), draw a line

on the floor where the back edge of the range will be.

Now install anti-tip brackets (see "Anti-Tip Brackets

Installation", page 10).

If range will not be installed against a cabinet, move

range into final position. Mark on the floor along both

sides of the range. If back of range will not be flush

with the wall (the location of the outlet may not allow

the range to be positioned against the wall), draw a

line on the floor where the back edge of the range will

be. Now install anti-tip brackets (see "Anti-Tip Brackets

Installation", page 10).

Gas Supply Installation

Figure 9

When shipped from the factory, this unit is designed
to operate on 4" water column (1.0 kPa) Natural gas
manifold pressure. A convertible pressure regulator (see
figure 2) is connected to the range manifold and MUST
be connected in series with the gas supply line. To access
the regulator, remove the drawer.

For proper operation, the maximum inlet pressure
to the regulator should be no more than 14" of water
column pressure (3.5 kPa).

The inlet pressure to the regulator must be at least 1"
(.25 kPa) greater than the regulator manifold pressure
setting. The regulator is set for 4" water column (1.0
kPa) Natural gas manifold pressure; the inlet pressure
must be at least 5" water column (1.25 kPa) Natural
gas. For LP/Propane gas, the regulator must be set for
10" water column (2.5 kPa) manifold pressure; the inlet
pressure must be at least 11" water column (2.75 kPa).

The supply line should be equipped with an approved
shutoff valve (see Figure 9). This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do not

Advertising