40" dual fuel range installation instructions, Electrical connection to the range – FRIGIDAIRE FPDF4085KF User Manual

Page 4

Advertising
background image

4

40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS

(Models with Electric Ovens and Gas Cooktop)

3.

Electrical Connection to the Range

Three Conductor Wire Connection to Range

If local codes permit connection of the frame grounding

conductor to the neutral wire of the copper power

supply cord (see Figure 3):

1. Remove the 3 screws at the lower end of the rear

wire cover, then bend the lower end of the rear

wire cover (access cover) upward to expose range

terminal connection block (see Figure 2).

2. Using the nuts supplied in the literature package,n

connect the neutral of the copper power supply cord

to the center silver-colored terminal of the terminal

block, and connect the other wires to the outer

terminals. Match wires and terminals by color (red

wires connected to the right terminal, black wires

connected to the left terminal) (see figure 3).

3. Lower the terminal cover and replace the 3 screws.

Figure 3

Silver Colored Terminal

1 1/8" (2.9 cm) Dia.

Direct Connection Hole.

Punch Out Knockout

for 1 3/8" (3.5 cm) Dia.

Cord Kit Hole.

To 240 V

Receptacle

A User Supplied

Strain-relief Must

Be Installed at This

Location.

Black

Wire

Terminal

Block

Cord

Mounting

Plate

Neutral

(White Wire)

Grounding

Strap

Red Wire

Four Conductor Wire Connection to Range

Where local codes does NOT permit connection of the

frame grounding conductor to the neutral wire of the

copper power supply cord (see Figure 4):

1. Remove the 3 screws at the lower end of the rear

wire cover, then raise the lower end of the rear
wire cover (access cover) upward to expose range
terminal connection block (see figure 2).

2. Remove the grounding strap from the terminal block

and from the appliance frame.

3. Using the nuts supplied with the literature package,

connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 4).

4. Connect the neutral of the copper power supply

cord to the center silver-colored terminal of the

terminal block, and connect the other wires to the

outer terminals. Match wires and terminals by color

(red wires connected to the right terminal, black
wires connected to the left terminal).

5. Lower the terminal cover and replace the 3 screws.

Terminal Block

Silver Colored Terminal

Red

Wire

Neutral

(White Wire)

Ground (Bare

Copper Wire)

To 240 V Receptacle

A User Supplied

Strain-relief Must

Be Installed at This

Location

Black Wire

1 1/8" (2.9cm)

Dia. Direct

Connection

Hole. Punch

Out Knockout

for 1 3/8"

(3.5cm) Dia.

Cord Kit Hole.

NOTE: Be sure to remove the

supplied grounding strap.

Figure 4

Advertising