System Messages

3-1-3 Master interrupt mask register failure

3-1-4 Slave interrupt mask register failure

3-2-2 Interrupt vector loading failure

3-2-4 Keyboard Controller Test failure

3-3-1 NVRAM power loss

3-3-2 NVRAM configuration

3-4-1 Screen initialization failure

3-4-2 Screen retrace failure

4-2-1 No time tick

4-2-2 Shutdown failure

4-2-3 Gate A20 failure

4-2-4 Unexpected interrupt in protected mode

4-3-3 Timer-chip counter 2 failure

4-3-4 Time-of-day clock stopped

4-4-1 Serial or parallel port test failure

4-4-4 Cache test failure

NOTE:

If the message you received is not listed in the table, see the documentation for either the operating system or the program that was running

when the message appeared.

 

Message

 

Possible Cause

 

Corrective Action

8042 Gate-A20

error

The keyboard controller
failed its test.

If you receive this message after you make
changes in the system setup program,
enter the system setup program and
restore the original value(s).

Address Line

Short!

An error in the address
decoding circuitry in the
memory has occurred.

Reseat the memory modules (see

Memory

).

C: Drive Error

C: Drive

Failure

The hard drive is not
working or is not configured
correctly.

Ensure that the hard drive is installed
correctly in the computer (see

Hard Drive

)

and defined correctly in the system setup
program (see

System Setup

).

Cache Memory

Bad, Do Not

Enable Cache

The cache memory is not
operating.

See "Contacting Dell" in your Owner's
Manual
for instructions on obtaining
technical assistance.

CH-2 Timer

Error

An error is occurring on the
timer on the system board.

See "Contacting Dell" in your Owner's
Manual
for instructions on obtaining
technical assistance.

CMOS Battery

State Low

CMOS Checksum

Failure

CMOS System

Options Not Set

CMOS Display

Type Mismatch

CMOS Memory

Size Mismatch

CMOS Time and

Date Not Set

The system configuration
information in the system
setup program is incorrect
or the battery charge may
be low.

Enter the system setup program (see

Entering System Setup

), verify the system

configuration, and then restart the
computer.

Diskette Boot

Failure

Drive A or B is present but
has failed the BIOS POST.

Ensure that the drive is installed correctly
in the computer (see

Drives

) and defined

correctly in the system setup program (see

System Setup

). Check the interface cable at

both ends.

DMA Error

DMA 1 Error

DMA 2 Error

Error in the DMA controller
on the system board.

The keyboard or system board may need to
be replaced.

FDD Controller

Failure

The BIOS cannot
communicate with the floppy
drive or hard drive

Ensure that the floppy drive or the hard
drive is installed correctly in the computer
(see

Drives

) and defined correctly in the

Advertising