Drives, skip to step 9. f – Dell PowerEdge 6850 User Manual

Page 24

Advertising
background image

22

SAS Information Update

4 Turn off your system, reseat the hard drive, and restart the system.

If the problem is not resolved, continue to the next step.

5 Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.

See the documentation supplied with the host adapter for information about the configuration utility.

6 Ensure that the hard drive has been configured correctly for the RAID.
7 Exit the configuration utility and allow the system to boot to the operating system.
8 Ensure that the required device drivers for your controller card are installed and are configured

correctly. See the operating system documentation for more information.

9 Check the cable connections inside the system:

a

Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.

b

Open the system. See "Opening the System" in the Installation and Troubleshooting Guide.

c

Verify that the cable connections between the SAS backplane(s) and the SAS controller card are
correct. See Figure 1-5.

d

Verify that the SAS cables are securely seated in their connectors.

e

Verify that the power connectors on the SAS backplane(s) are securely seated in their connectors.

f

Close the system. See "Closing the System" in the Installation and Troubleshooting Guide.

g

Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help" in the Installation and Troubleshooting Guide.

Advertising