Operating controls and indicators – Cissell CAB438C User Manual

Page 10

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Operation

AJ0975

8

Operating Controls and Indicators

Refer to Figure 3.

Table 1 (Continued)

Controls or

Indicators

Function

Position or Indication

1. Red stop button

Stops electrical service to blowers, timers, and heat exchanger.

Press to actuate.

2. Cycle timer control
knob

Determines pressing cyle time.

Rotate knob to desired
setting.

3. Steam timer control
knob

Determines the length of sleeve steaming time. Normally set at

5 seconds.

Rotate knob to desired
setting.

4. Water gun needle
valve

Turns water on and off to water spray gun.

Turn clockwise to turn
water off. Turn
counterclockwise to turn
water on.

5. Reset button

Energizes the air power control circuit. Press must be reset if press gauge
(item 6) registers 0 psi.

With buck in the out
position, press reset
button.

6. Gauge, reset system

Indicates that air power is on or off to press.

When gauge shows line
pressure, air is reset to
press. When gauge shows
zero pressure, air must be
reset for press to operate.

7. Right gray buck in
button

When pressed simultaneously with the left gray buck in button
(item 13), moves buck from dressing position to pressing position inside
cabinet.

Press simultaneously
with left gray buck in
button (item 13) to
actuate.

8. Black vacuum
release button

Turns vacuum off to buck.

Press to actuate.

9. Emergency Stop
button

Exhausts entire air system except for air to collar clamp air cylinder.
Stops buck travel and opens press heads or keeps press heads from
closing. Press will not operate until air circuit is reset. (Applies to
machines produced after 1997.)

Press to actuate. Turn in
direction of arrow on
button to reset. Button
will pop up after
approximately 1/8 turn.

10. Collar clamp foot
pedal

Opens clamping arm on collar clamp (item 16).

Depress foot pedal to
open collar clamp.
Release foot pedal to
close collar clamp.

11. Sleeve extender/
vacuum foot pedal

Moves the sleeve extenders out and turns vacuum on to buck.

Depress foot pedal to
actuate.

12. Sleeve extender
release button

Retracts sleeve extenders, which brings them in toward the buck. Should
be actuated before dressing shirt on buck.

Press to actuate.

13. Left gray buck in
button

When pressed simultaneously with the right gray buck in button
(item 7), moves buck from dressing position to pressing position inside
cabinet.

Press simultaneously
with right gray buck in
button (item 7) to actuate.

14. Red head release
button

Opens the press heads. Buck will automatically return to the dressing
position when heads open.

Press to actuate.

Advertising