Post-operating services cleaning press heads, Warning – Cissell CAB438C User Manual

Page 14

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Operation

AJ0975

12

Post-Operating Services

Perform the following services after the final operation
of the day or anytime press will be idle for an extended
period of time:

1. Turn off steam to buck sleeve openings by

pressing the steam Timer Selector switch to the
off position.

2. Mist air bags with water and send unloaded buck

into pressing cabinet (this will prolong the life of
the air bag and eliminate formation of wrinkles in
air bags). Repeat 4 times.

3. Press one safety bar to relieve air pressure and

stop blower.

4. Open customer-furnished electrical disconnect

switch or trip the circuit breaker.

5. Close steam shut-off valve.

6. Close shut-off valve at air inlet.

7. Clean buck padding with a damp cloth. Check

condition of buck padding and air bags. Replace
padding if:

Cover is scorched or torn.

Bags have holes.

Flannel is hard or brittle (not springy).

8. Clean press heads if required.

Cleaning Press Heads

Press heads require cleaning if:

Discoloration transfers from head to shirts.

Shirts stick to heads as the heads open.

Once precautions listed in these WARNINGS have
been met, follow directions provided with surface
cleaner to clean press heads.

To avoid possible serious injury, heads
should be cleaned ONLY by properly
trained personnel.

W376

WARNING

To avoid possible serious injury, ALWAYS
shut off services to press BEFORE
removing guards and covers to clean
press heads.
• Shut off AND lock out ALL electrical

power to press.

• Shut off AND lock out ALL air pressure

to press using the relieving shut-off
valve at air supply inlet.

• Reduce steam pressure to 0 AND lock

out steam supply to press.

• Let heated surfaces cool.

W377

WARNING

If using a surface cleaner which requires
heat to the press, use an industry
approved heat protective mitt or other
heat protective device as press heads are
cooling down.

W378

WARNING

Advertising
This manual is related to the following products: