Instruction manual oil-less compressors – Curtis OL 512 User Manual

Page 32

Advertising
background image



CAP-215

19

Instruction Manual Oil-Less Compressors



5.

AUTOMATIC CONDENSATE DRAIN


5.1. DESCRIPTION

The condensate drain valve should drain the final separator (1 -stage compressor) or the intermediate and final

separator (2-stage compressor) every 15 minutes or earlier if necessary.


Furthermore, condensate is drained after each operation (stand still drainage).


A solenoid valve is installed as a condensate drain valve, which is open when it does not receive any

power. It works electro-pneumatically.


5.2. FUNCTION

The solenoid valve closes as soon as it receives current, thus condensate can be collected in the separators.

Power supply is interrupted every 15 minutes, the solenoid valve opens and condensate can be drained.


The solenoid valve is de-energized and opens after the compressor has been shut down. Thus the separators

are drained at down-time.

Advertising