Instruction manual oil-less compressors – Curtis OL 512 User Manual

Page 40

Advertising
background image




CAP-215

27

Instruction Manual Oil-Less Compressors



9. MAINTENANCE

SCHEDULE


9.1. MAINTENANCE INTERVALS

Interval

Maintenance Work

Sec.

1/2 hour after start-up

Manual check of valve function (at first operation and maintenance

4

work

250 operating hours

Check all connections for leakage

--

50 - 250 operating hours Service intake filter (according to degree of pollution), never wash

2

4,000 operating hours

Check pistons and piston rings of 2nd stage, replace if necessary

--

(at least every 3 years)

Dismantle valves, clean, check, and replace if necessary

4

Check all threaded pipe unions

--

Clean sinter-filters of the separators

3

10,000 operating hours

Check pistons and piston rings of 1st stage, replace if necessary

--

(at least every 3 years)

Check plate valves, replace if necessary

--

Check conrod bearing and piston pin bearing, replace if necessary

--

20,000 operating hours

Check driving gear main bearing, replace if necessary

--

(at least every 3 years)


9.2. MAINTENANCE

RECORD


We recommend that all maintenance work is recorded in a service book, showing the date and details of the

work carried out. This will help to avoid expensive repair work caused by missed maintenance work.


If it is necessary to file a claim against the warranty, it would help to have proof that regular maintenance work

has been carried out and that the damage has not been caused by insufficient maintenance. Please refer to

DIS-7 “Limited Warranty Information”.


For this purpose maintenance (control sheets are provided in the annex of this instruction manual. Please mark

the appropriate box(es) to show what maintenance work has been carried out and the number of hours of

service, then sign and date.

Advertising
This manual is related to the following products: