Instruction manual oil-less compressors – Curtis OL 512 User Manual

Page 37

Advertising
background image




CAP-215

24

Instruction Manual Oil-Less Compressors



8.1.1. Natural

ventilation


As warm air rises, adequate wall openings should be provided for cooling air intake (next to the floor) and for

cooling air outlet (next to/ in the ceiling).


The compressor should be positioned right next to the air inlet opening.

Fig. 16: Installation with natural ventilation


A Minimum distance from wall, intake side 1.6405 ft.


B Minimum distance from wall, exhaust air side 2.46075 ft


The opening for intake air A2 should be approx. 20% larger than the opening for exhaust air A3 taking into

account louvers, grills, etc.


The table in Fig. 16 is based on the following values:


Room

temperature

87°F

Temperature

variation

with

natural

ventilation

27°F

Thickness

of

walls

9.8425

in.


If it is not possible to follow the recommended guide lines for natural ventilation (e.g. installation of several

compressors within a very small operating room), the operating room must be ventilated artificially.