Instruction Manual Oil-Less Compressors



12.

TROUBLE-SHOOTING


TROUBLE

CAUSE

REMEDY

Compressor
Compressor does not reach

Condensate drain valve(s) and/

Tighten and reseal

final pressure

or fittings leaking
Premature opening of final safety

Clean final safety valve and re-

valve

adjust

Piston rings worn

Replace

Excessive piston clearance

Replace

Compressor output insufficient

Pipes leaking

Re-tighten

Safety valves between individual

Intermediate pressure too high

Check valves - see chapter 4 -

stages releasing pressure

Valves not closing properly

service and clean valves

Compressor running too hot

Insufficient supply of fresh

Check location max. ambient

cooling air

temperature + 40º C (105º F)

Intake or outlet valves not closing

Check and clean valves, replace

properly

as necessary

Wrong direction of rotation

See arrow on compressor and
remedy accordingly

Control does not switch off,

Final pressure switch set too high

Correct setting

final pressure safety valve relieving

Final pressure safety valve defective Replace safety valve

Automatic: Condensate Drain (optional)
Drain valves do not close

No control air

Check control air line

Drain valves leaking

Dismantle drain valve and clean

Drain valves do not open

Condensate drain valve piston seized Dismantle drain valve, clean or

replace valve

Solenoid valve does not close

Solenoid valve faulty

Check solenoid valve and replace
if necessary

No electrical signal

Check for voltage from timer

Solenoid valve does not open

Solenoid valve faulty

Check solenoid valve and replace
if necessary

Continuous electrical signal

Check electrical control circuit and
timer