Reserved Join Numbers

A reserved join number is a feature of the software that enables a designer to create a
button on a touchpanel page that either calls up the Setup Menu, ramps contrast, etc.
The table shown below provides a list of reserved join numbers available within the
software.

Reserved Join Numbers for Series 3200 Touchpanels

JOIN NUMBER

FUNCTION

VALUE

1016

Brightness

On

1017

Brightness

Low

1018

Brightness

Medium

1019

Brightness

High

1023

Contrast

Up

1024

Contrast

Down

1035

Call up Setup Menu

Not Applicable

1160

Keyclick Volume

Up

1161

Keyclick Volume

Down

1172

Keyclick

On

1173

Keyclick

Off

Problem Solving

Troubleshooting

The table below and on the next page provides corrective action for possible trouble
situations. If further assistance is required, please contact a Crestron customer
service representative.

Series 3200 Touchpanel Toubleshooting

TROUBLE

POSSIBLE

CAUSE(S)

CORRECTIVE ACTION

Touchpanel
does not
function.

Touchpanel is not
communicating to the
network.

Use Performance Viewport (via SIMPL Windows
or VT Pro) to poll the network. Verify network
connection to the touchpanel.
Verify touchpanel is in "CRESNET II" mode as
defined in "Interface Menu", page 13.

Touchpanel is not
receiving network
power.

Confirm that power is supplied to the network.

Touchpanel is
incorrectly calibrated.

Enter "SETUP MODE" and recalibrate.

Operations Guide - DOC. 5725