Power distribution board, Removing the power distribution board – Dell PowerEdge R905 User Manual

Page 138

Advertising
background image

138

Installing System Components

Chassis intrusion switch cable

SATA interface cable

8 Install all expansion cards. See "Installing an Expansion Card" on page 80.
9 Reinstall the SAS controller card. See "Installing a SAS Controller Card"

on page 114.

10 If applicable, reconnect the RAID battery cable to the SAS controller card.
11 If applicable, reinstall and connect the RAC card. See "Installing an

Optional RAC Card" on page 86.

12 Reinstall the NIC daughter card. See "Installing the NIC Daughter Card"

on page 91.

13 Install the optical drive carrier.

Slide the drive carrier into its drive bay and press in the release latch. See
Figure 3-19.

14 Install the SAS hard drives in their original locations. See "Installing a Hot-

Plug Hard Drive" on page 111.

15 Replace the riser card.
16 Replace the cooling shroud assembly. See "Replacing the Cooling Shroud

Assembly" on page 72.

17 Replace the PEM.
18 Close the system. See "Closing the System" on page 68.
19 Reconnect the system to its electrical outlet and turn the system on,

including any attached peripherals.

20 Replace the bezel. See "Removing and Replacing the Optional Front

Bezel" on page 66.

Power Distribution Board

Removing the Power Distribution Board

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and

Advertising