Dell PowerEdge R905 User Manual

Page 23

Advertising
background image

About Your System

23

E122A

CPU # VTT

Processor # VTT voltage
has exceeded the
allowable voltage range

See "Getting Help" on
page 181.

E122D

CPU # VDDIO

Processor # VDDIO
voltage has exceeded the
allowable voltage range

See "Getting Help" on
page 181.

E122E

CPU # VDDA

Processor # VDDA
voltage has exceeded the
allowable voltage range

See "Getting Help" on
page 181.

E122F

2.5V PwrGd

2.5V voltage regulator has
failed.

See "Getting Help" on
page 181.

E1231

1.2V HTCORE

PwrGd

1.2V HTCORE voltage
regulator has failed.

See "Getting Help" on
page 181.

E1232

VDD 12V PS#

PwrGd

The specified power
supply has failed or has
been removed from the
bay while the system
was on.

If removed, reinsert the
power supply into the bay
and reconnect to power.
For component failures,
see "Getting Help" on
page 181.

E123B

LOM Mezz

PwrGd

Voltage regulator for the
NIC daughter card has
failed.

Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 181.

E123C

Planar LOM

PwrGd

Voltage regulator for the
integrated NIC has failed.

Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 181.

E1310

RPM Fan ##

RPM of specified cooling
fan is out of acceptable
operating range.

See "Troubleshooting
System Cooling
Problems" on page 157.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions

Advertising