About Your System

Table 1-8.

System Messages

Message

Causes

Corrective Actions

Alert! Node

Interleaving

disabled! Memory

configuration does

not support Node

Interleaving.

The memory
configuration does not
support node
interleaving. The system
will run but with reduced
functionality.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. See
"General Memory Module
Installation Guidelines" on
page 94. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.

Attempting to

update Remote

Configuration.

Please wait...

Remote Configuration
request has been detected
and is being processed.

Wait until the process is
complete.

BIOS Manufacturing

mode detected.

MANUFACTURING MODE

will be cleared

before the next

boot. System

reboot required

for normal

operation.

System is in
manufacturing mode.

Reboot to take the system
out of manufacturing
mode.

BIOS Update

Attempt Failed!

Remote BIOS update
attempt failed.

Retry the BIOS update. If
the problem persists, see
"Getting Help" on
page 181.

Caution! NVRAM_CLR

jumper is

installed on

system board.

NVRAM_CLR jumper is
installed. CMOS has
been cleared.

Remove the NVRAM_CLR
jumper. See Figure 6-1 for
jumper locations.