About Your System

47

Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.

The system configuration of

processor, memory modules,

and expansion cards may not

be supported by the power

supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If Energy Smart

power supplies are installed,

replace them with the High

Output power supplies to

use the components. See

"Power Supplies" on

page 117.

Warning! PSU
mismatch. PSU
redundancy lost.
Check PSU.

A High Output power supply

and an Energy Smart power

supply are installed in the

system at the same time.

Install two High Output or

two Energy Smart power

supplies in the system.
You can also run the system

on one power supply until

you can obtain two power

supplies of the same type.

See "Troubleshooting Power

Supply" on page 143.

Warning!
Unsupported
memory
configuration
detected. The
memory
configuration is
not optimal. The
recommended
memory
configuration
is: <message>.

Invalid memory

configuration. The system

will run but with reduced

functionality.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 98.

If the problem persists,

see "Troubleshooting System

Memory" on page 145.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions