3.0

FUNCTIONAL DESCRIPTION


3.1

GENERAL


The VX462B is configured, controlled, and statused through on-board registers accessible
through the VXI backplane. These registers control the mode of operation, pulse repetition
interval, pulse width, delay time, output amplitude and an output relay. A simplified block
diagram of the module is shown in Figure 2.

CONTROL

DATA BUS

ADDR BUS

ADDR BUS

CONTROL

DATA BUS

TRIG OUT

TRIG IN/GATE

PULSE OUT

LOGIC

CONTROL

ADDRESS

DECODE

VXI &

USER

REGISTERS

PULSE

GENERATOR

LOGIC

VXI

INTERFACE

Figure 2. Simplified Block Diagram



3.2

SWITCHES AND JUMPERS


The following switches are used to
configure the VX462B. Refer to
Figure 3 for the switch and jumper
locations.

LOGICAL ADDRESS An 8-bit
logical address switch is provided
to uniquely identify the module in
the system. Refer to Section 4 for
switch definition.

OUTPUT IMPEDANCE The
VX462B can be configured with a
50 Ohm or a 2 Ohm output
impedance. Install a jumper in J5
only for 2 Ohms, and J6 only for
50 Ohm series output impedance.

Logical Address

Selection

128

1

0

1

P1

P2

J6

J5

50 Ohm

2 Ohm

Output Impedance

Selection

Figure 3. Hardware Configurable Controls