Figure 6. pri register – CH Tech Pulse Generator User Manual

Page 17

Advertising
background image

11


3.5.2 Pulse Configuration Registers

Pulse Repetition Interval Register (08) This read/write register controls the pulse repetition
interval and the state of the output relay. See Figure 6 for details.

08

PRI Register

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

OEN

Range

Not Used

PRI Multiplier

Read

OEN

Range

Not Used

PRI Multiplier

OEN

Output Relay Enable (1 = enabled/output on)

Range

PRI & Delay Range

bit 14 13 12

0 0 0 25 ns

0 0 1 100 ns

0 1 0 1

s

0 1 1 10

s

1 0 0 100

s

1 0 1 1 ms

1 1 X invalid

PRI Multiplier

PRI Multiplier (period = PRI Multiplier

Range)

NOTES:

1) The Range field is used for both the PRI and Delay time settings.

2) The minimum programmable period is 100 nsec. Therefore the minimum PRI

Multiplier is 4 in the 25 nsec range, and 2 for all other ranges.

3) The maximum PRI Multiplier is 1023; therefore, the maximum programmable period

is 1.023 sec.

4) For highest accuracy use the smallest range with a larger multiplier.

Figure 6. PRI Register