10

Table 2. SEL Event Logs for Machine Check Errors

Error Type

Gen ID

EvMRev Sen Type Sen # Ev Dir/Type

Data 1

Data 2

Data 3

Processor Specific
Fatal

0x31 0x4

0x7 N/A 0x6F

0xA0

Index to SMBIOS
Type4 record

Severity - 0x01

Uncorrectable

0x31 0x4

0x7 N/A 0x6F

0xA0

Index to SMBIOS
Type4 record

Severity - 0x00

Correctable

0x31 0x4

0x7 N/A 0x6F

0xA0

Index to SMBIOS
Type4 record

Severity - 0x02

Memory DIMM specific

Uncorrectable

0x33 0x4

0xC N/A 0x6F

0x81

0xFF

Bit 7:6 – Index to
SMBIOS
Type16 record
Bit 5:0 – Index to
SMBIOS Type
17 record

Correctable

0x33 0x4

0xC N/A 0x6F

0x80 0xFF

Bit 7:6 – Index to
SMBIOS
Type16 record
Bit 5:0 – Index to
SMBIOS Type
17 record

PCI Device Specific

SERR

0x31

0x4

0x13

0x6F

0xA4

PCI Bus #

Bit 7:3 -DEV#
Bit 2:0 -Func#

PERR

0x31

0x4

0x13

0x6F

0xA5

PCI Bus #

Bit 7:3 -DEV#
Bit 2:0 -Func#

PCI Bus PERR/SERR
SERR

0x31

0x4

0x13

N\A

0x6F

0x84

PCI Bus #

0xFF

PERR

0x31 0x4 0x13 N\A 0x6F

0x85 PCI

Bus

#

0xFF

Processor Bus, LPC Bus, SP port, HL Bus, non-specific Bus Errors
Uncorrectable

0x31 0x4

0x13 N/A 0x6F 0x08

0xFF

0xFF

Correctable

0x31 0x4

0x13 N/A 0x6F 0x07

0xFF

0xFF