Specific post code modules, Sal-a module, 2 specific post code modules – Dell PowerEdge 7250 User Manual

Page 26: Table 6. sal-a post codes (bsp only)

Advertising
background image

POST Codes

SR870BN4 Error Reference Guide

Revision

1.0

20

Code Value (bit 8 = 1,
bits 11:4 shown below)

Module Display

0xF2

Memory Autoscan (stackless)

North

SUB MODULES

BITS

15:12 11:8 7:4 3:0

Memory Autoscan

8 F

2

0

Pass1 Entry

8 F

2

1

Process Auto Scan Input

8 F

2

2

Execute Auto scan (C- code)

8 F

2

3

Process Auto Scan Output

North

0xF1 Recovery

stackless

North

0xF0 Reserved

North

0xEF-0xEE

Memory Autoscan C-code

North

0xED-E8 Recovery

C-Code

0xE8-0xE6 HOB

North

0xE5-0xC1 Reserved

North

0xC0

SALA to SALB/DXE handoff

North

0xB0-0xBF Reserved

North

0xAF-80

Reserved for SAL
MCA, INIT, PMI

North

0x7F to 0x60

SAL-B codes
SAL-B
SAL_C
SAL_F


South
South
South

0x60

SAL to EFI handoff

South

0x5F to 0x50

EFI

South

0x4F to 0x40

ACPI

South

7.2.2

Specific POST code Modules

7.2.2.1 SAL-A

Module

The SAL-A POST codes are defined in the following table.

Table 6. SAL-A POST Codes (BSP Only)

Code Number

Meaning

Display

0x8FE0 Reset

Condition

North

0x8FD0

Node BSP selection

North

0x8FC0

Early node init (SNCPEIM)

North

0x8FB0

Processor health/setup (CVDR PEIM)

North

0x8FA0

PAL/FW health status

North

0x8F70

Memory Initialization Entry

North

0x8F71

RAC Initialization (Mem_DoRacInitialization()) North

Advertising