BIOS POST Error Codes and Messages

SR870BN4 Error Reference Guide

Revision

1.0

16

Error Code

Error Message

Pause on Boot

Recommended User Action

8504

Persistent Single-bit Error
Detected Row1. Row 1 mapped
out

Yes

Verify the affected memory and
replace with correct memory.

8505

Persistent Single-bit Error
Detected Row2. Row 2 mapped
out

Yes

Verify the affected memory and
replace with correct memory.

8506

Persistent Single-bit Error
Detected Row3. Row 3 mapped
out

Yes

Verify the affected memory and
replace with correct memory.

8507

Persistent Single-bit Error
Detected Row4. Row 4 mapped
out

Yes

Verify the affected memory and
replace with correct memory.

8508

Memory Mismatch detected Row1.
Row 1 mapped out

Yes

Verify the affected memory and
replace with like memory.

8509

Memory Mismatch detected Row2.
Row 2 mapped out

Yes

Verify the affected memory and
replace with like memory.

850A

Memory Mismatch detected Row3.
Row 3 mapped out

Yes

Verify the affected memory and
replace with like memory.

850B

Memory Mismatch detected Row4.
Row 4 mapped out

Yes

Verify the affected memory and
replace with like memory.

850C

DIMM1, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

850D

DIMM2, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

850E

DIMM3, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

850F

DIMM4, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

8510

DIMM5, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

8511

DIMM6, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

8512

DIMM7, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

8513

DIMM8, memory board 1
defective.

Yes

Verify the affected memory and
replace with good memory.

8514

DIMM1, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

8515

DIMM2, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

8516

DIMM3, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

8517

DIMM4, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

8518

DIMM5, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

8519

DIMM6, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

851A

DIMM7, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.

851B

DIMM8, memory board 2
defective.

Yes

Verify the affected memory and
replace with good memory.