Programming, Arming mode selection (passive or active arming), Ignition controlled door locking / unlocking – Clarion UNGO MS3001 User Manual

Page 16: System initialization and default reset

Advertising
background image

Page 14 - MS3001 / MS3200 Installation Manual

Arming Mode Selection (Passive or Active Arming)

Using the Remote Transmitter, you may select Passive Arming with chirp confirmation, Passive
Arming without chirp confirmation, or Active Arming (Remote only).

To set the Arming Mode:

1. Turn the ignition on.
2. Within 4 seconds, press Transmitter Buttons 1 and 2 together.

First push:

one chirp

=

Passive Arming with chirp

Second push:

two chirps

=

Active Arming

Third push:

three chirps

=

Passive without chirp

3. Turn off the ignition key to save your selection.

Ignition Controlled Door Locking / Unlocking.

Selects whether or not the system automatically locks the doors when the ignition is turned on.
When selected, the Ignition Controlled Door Locking feature will automatically lock the doors 10
seconds after the ignition key is turned on and automatically unlock the doors when the ignition
key is turned off.

To set Ignition Locking / Unlocking:

1. Turn the ignition on.

2. Within 4 seconds, press Transmitter Button 2.

The siren will chirp to indicate the setting.
one chirp

= On

two chirps

= Off

3. Press Transmitter Button 2 again to change the setting.

4. Turn off the ignition key to save your selection.

To prevent the keys from being locked inside the vehicle when Ignition Controlled Door
Locking is on:

• The system will not lock the doors if any door is open when the ignition is turned on.
• The system will not lock the doors if any door is opened during the 10 second

countdown.

System Initialization and Default Reset

Following this procedure will set all System Programming Parameters to factory default settings.

1. Turn the ignition on.

2. After 4 seconds, press and hold Buttons 1 and 2 together for 2+ seconds.

The siren will emit one chirp, indicating that the reset signal was received.

3. Turn ignition off.

• All System Programming parameters are now set to factory default settings.
• The Arming Mode is set to Remote Arming only.
• The Valet Mode is off.
• The Shock Sensor Trigger sensitivity is set to Level 4.
• The Shock Sensor Warn-Away sensitivity is set to High.

4. Turn off the ignition key to save your selection.

Programming

install_MS3001.qxd 8/11/99 4:15 PM Page 14

Advertising
This manual is related to the following products: