There are 2 different ways to close the gate (entering or exiting):
1.

Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave).

2.

Interrupt Loop: clearing the Inside Interrupt Loops cause the gates to close (Master or Slave).

NOTE: To ensure gate closure, set Reclose Timer = ON in both Master and Slave units.
INPUT CONNECTIONS: Refer to Part 2 Master/Slave Layout and Wiring, for more details
• Master and Slave units require their own separate inputs.
• If Radio inputs are used in both units, each requires its own transmitter and entry code.