Figure 14. Bi-Part, Uni-Directional Gate System

(Swing gate opens out).

* WARNING

If Radio is used, gate system becomes bi-directional, compromising safety and security.

Figure 15. Bi-Part, Bi-Directional Gate System.

NOTE: If Radio is used, only one receiver/transmitter is required for both directions.

Gate

Operator

Master

Gate

Operator

Slave

Exit Loop

Swing gate open

direction and its

maximum arc.

Inside Interrupt Loop

Outside Interrupt Loop

Swing Gate

Swing Gate

Fence

Fence

Additional

Master Wiring

(if needed):

Fire

Manual Inputs

Interrupt Bar

Photo-Sensors

MagLock

Warning Relay

Tel. Line

1398F10

Shadow Loop

Master/Slave Cable

Can use Radio or Cycle if

Exit Loop is not used.

Gate

Operator

Master

Gate

Operator

Slave

Directional Exit Loop

Swing gate open

direction and its

maximum arc.

Directional Exit Loop

Inside Interrupt Loop

Outside Interrupt Loop

Slide, Barrier or Swing Gate

Slide, Barrier or Swing Gate

Fence

Fence

Additional

Master Wiring

(if needed):

Fire

Manual Inputs

Interrupt Bar

Photo-Sensors

MagLock

Warning Relay

Tel. Line

1398F11

Master/Slave Cable

Shadow Loop

(swing gates only)

Can use Radio or Cycle if

Exit Loop is not used.

Can use Radio or Cycle if

Exit Loop is not used.