Rev E

Doc 01-20201

27 of 33

Figure 25. Bi-Directional Tandem Gate System

(Swing gate opens out).

NOTE: If Radio is used, only one receiver/transmitter is required for both directions.

Gate

Operator

Master

Gate

Operator

Slave

Directional Exit Loop

Swing gate open

direction and its

maximum arc.

Directional Exit Loop

Outside Interrupt Loop

Inside Interrupt Loop

Inside Interrupt Loop

Outside Interrupt Loop

Slide or Barrier Gate

Swing Gate

Additional

Master Wiring

(if needed):

Fire

Manual Inputs

Interrupt Bar

Photo-Sensors

MagLock

Warning Relay

Tel. Line

Additional

Slave Wiring

(if needed):

Manual Inputs

Interrupt Bar

Photo Sensors

MagLock

Warning Relay

1398F21

Master/

Slave

Cable

Shadow Loop

Can use Radio or Cycle if

Exit Loop is not used.

Can use Radio or Cycle if

Exit Loop is not used.