Part 2 master/slave layouts and wiring, Biparting slide gates, Figure 6. biparting slide gate photo-sensor layout – Chamberlain SL 1000-B3 User Manual

Page 13

Advertising
background image

Rev E

Doc 01-20201

10 of 33

PART 2

MASTER/SLAVE LAYOUTS AND WIRING

A. PHOTO-SENSOR INSTALLATION FOR BIPARTING GATE CONFIGURATION

BIPARTING SLIDE GATES

Figure 6. Biparting Slide Gate Photo-Sensor Layout.

WARNING

Buy only UL-approved photo-sensors made for use with vehicular gate
operators or system. Otherwise, safe gate operation may be compromised.

IMPORTANT NOTE: The installation shown in Figure 6 above is a suggested layout using emitters
and receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area
of gate travel to be effective.

Install photo-sensors in three Coverage Areas as shown in Figure 6.
1. Coverage Area A - Inside-Open Coverage:

Install two photo-sensors: Inside the fence line, from the gate operators to the gate fully open
positions.

2. Coverage Area B - Inside-Closed Coverage:

Install one photo-sensor: Inside the fince line, from the Master gate operator to the Slave gate
operator.

3. Coverage Area C - Outside-Closed Coverage:

Install one photo-sensor: Outside the fence line, from one fence edge to the other.

4. Connect the photo-sensors to whichever unit is most convenient. For wiring instructions,

see Section C, Connecting Input Wiring, below.