Figure 8. Biparting Barrier Gates Photo-Sensor Layout.

WARNING

Buy only UL-approved photo-sensors made for use with vehicular gate
operators or system. Otherwise, safe gate operation may be compromised.

IMPORTANT NOTE: The installation shown in Figure 8 above is a suggested layout using emitters and
receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area of
gate travel to be effective.

Install photo-sensors in three Coverage Areas as shown in Figure 8.
1. Coverage Area A - Inside-Open Coverage: not needed in barrier gate installation.
2. Coverage Area B - Inside-Closed Coverage:

Install one photo-sensor: Inside the fince line, from the Master gate operator to the Slave gate
operator.

3. Coverage Area C - Outside-Closed Coverage:

Install one photo-sensor: Outside the fence line, from one fence edge to the other.

4. Connect the photo-sensors to whichever unit is most convenient. For wiring instructions, see

Section C, Connecting Input Wiring, below.

B. PHOTO-SENSOR INSTALLATION FOR TRAP/TANDEM GATE CONFIGURATION

Photo-sensors must be installed on each gate separately. For instructions see the Installation and
Operation Manual for the gates.