INSTAllATION
INSTRUCTIONS

NOTE: This heater has a continuous fan-only feature. See
page 4,

Operation Instructions, step #4 for details.

Installation of Back Box in New Construction

1. Mounting Back Box (See Figure 1).

a. Place the back box between two 16" (406 mm) center-

to-center wall studs at the desired mounting height but
no closer than 8" (203 mm) to adjacent wall or floor.

NOTE: If wall studs are spaced greater than 16” on center,
additional framing supports may be necessary.

b. Align back box such that the bottom and sides will be

flush with finished wall surface (top flange of back box
should protrude approximately 1/2" (12.7 mm) from
finished wall surface).

c. Secure the back box in position with wood screws or

nails as shown in Figure 1.

Not for ceiling mount.

2. Power Supply Wiring (See Figure 1)
NOTE: Wire compartment volume - 119 in

3

(1950 cm

3

).

a. Run a power supply cable into the knockout area in the

upper right hand corner of the back box. All wiring must be
in accordance with National and Local Electrical Codes.
Refer to Table 1, page 1 for correct wire size.

b. Remove disconnect switch bracket by loosening two

screws on the right side.

c. Install a cable clamp in the knockout in the top of the back

box.

d. Insert power supply cable through cable clamp, allowing at

least 6" (152 mm) of leads to extend inside the back box.
Connect the blue lead wires of disconnect switch to the
supply wire leads using wire connectors (see Wiring
Diagrams, page 5).

e. Ground the back box by connecting the supply ground

lead wire to the green ground screw located in the inside
top of the back box.

f. Secure disconnect switch bracket in place by tightening

screws.

Installation of Back Box in Existing Construction

1. Provide a wall opening 14-1/2" (362 mm) wide by 18-1/2"

(470 mm) high at the desired mounting height, but no closer
than 8" (203 mm) to adjacent wall or floor. (See Figure 2.)

NOTE: Locate so at least one side of opening is at wall stud.

2. Power Supply Wiring

To prevent a possible fire, injury to persons or damage to the
heater, adhere to the following:
1. Disconnect all power coming to heater at main service

panel before wiring or servicing.

2. All wiring procedures and connections must be in

accordance with the National and Local Codes having

jurisdiction and the heater must be grounded.

3. Power supply must enter back box through the knockouts in

the RIGHT side of box(see Figure 1). See also TOP

marking on the back box for proper orientation.

4. Verify the power supply voltage coming to heater matches

the ratings as shown on the heater nameplate.

CAUTION: ENERGIzING HEATER AT A VOLTAGE GREATER

THAN THE VOLTAGE PRINTED ON THE NAMEPLATE

WILL DAMAGE THE HEATER AND VOID THE WARRANTY

AND COULD CAUSE A FIRE.

5.

CAUTION - High temperature, risk of fire, keep electrical

cords, drapery, furnishings, and other combustibles at least

3 feet (0.9 m) from front of heater. Do not install heater

behind doors, below towel racks, in the ceiling or in an area

where it is subject to being blocked by furniture, curtains or

storage materials. Hot air from the heater may damage

certain fabrics and plastics.

6. To reduce the risk of fire, do not store or use gasoline or

other flammable vapors and liquids in the vicinity of the

heater.

7. This heater is to be mounted only using back box and may

be installed with the back box recessed or surface mounted

as described within this manual.

8. The following minimum clearances must be maintained:

Bottom of heater to floor - 8” (203 mm).
Sides of heater to adjacent wall - 8” (203 mm).
Top of heater to ceiling - 36” (915 mm).

9. Do not operate the heater without the grille installed.
10. Do not use this heater for dry out as the paint, plaster,

sawdust and drywall sanding dust will permanently damage

the heater and must be kept out of the heater.

Fig. 1: Locating Recessed Back Box in New Construction

BACK BOX

Fig. 2: Locating Recessed Back Box in Existing Construction

BACK BOX