HARDWARE INSTALLATION – CALIBRATION

13

Retry

Press and hold panic and shutter button

simultaneously more than 2 sec for calibration

Press any single button to escape

Park vehicle on a flat surface with

at least 50 meters of space directly ahead

and press panic button once

G-Sensor Calibration is finished successfully

Press any button or wait 30 seconds to reboot

If G-Sensor Calibration has failed,

Park vehicle on a flat surface with

At least 5 meters of space directly ahead

And press panic button once again

Move directly forward and accelerate vehicle till beep

sound occur

9) After power cables and trigger cables are properly connected and the
BX4000 system is installed, The internal G-Sensor must be calibrated. It
detects the installed direction of the BX4000 (vertically or horizontally) for it to
accurately record the journey direction.

Press and hold [PANIC] & [SHUTTER] button together and then power on
(turn on ignition).

This G-Sensor calibration is only needed at the first time the BX4000 is used.

Panic Button

Shutter Button