Slide number 15, Function (main unit) – RearviewSafety RVS-4000 User Manual

Page 15

Advertising
background image

FUNCTION (MAIN UNIT)

Automatic start

Make sure that peripherals, including cameras, are properly connected.
Turn on the vehicle power, BX4000 will automatically start. (Use the power
cable provided.)

Event recording

The Event recording will be started automatically by Motion detection, Alarm1,
Alarm 2, Alarm 3, and/or by the G-sensor level.

The emergency recording can be activated by pressing the [PANIC] button.

15

Notice : The unit will not start recording immediately after the power is
turned on. It takes up to 1 minute for the built-in power backup system
to charge. Thereafter, the internal flash memory will be ready to record.

Normal recording (Continuous record)

The Normal (continuous) recording will be automatically started after power up.
BX4000 will not make a separate event file during the continuous recording.
It will mark or “flag” the Event area as ‘Alarm1~3’, G-senor, Motion detection or
[PANIC] button in the continuous recording file, which can be easily searched for
during playback. The alarms can also be displayed on the video image.

Live image on LCD Monitor

BX4000 will display the live video image on the LCD monitor.
The camera channel can be changed using the information on the OSD.
(Refer to page 13)

Playback in the car

Recorded files can be played back in the car using LCD monitor and remote.

PC Viewer Software

The software is pre-loaded on the SD card in the “pcsw” folder.

Dual record Mode (Event & Normal record)

If you set different record modes per camera, i.e camera1 set as Event record
and camera 2 set as Normal record, then camera1(Event record) will work
according to the record setting for example 10 frames per second recording.
However camera2 (Normal record) will record 1frame per second, if there is no
event. If there is an Event, both cameras will record according to the record
setting for example 10 frames per second recording.

Advertising