Identity code, Configuring the touchpanel, G-series touchpanels – Crestron electronic Isys G-Series TPS-15G-QM User Manual

Page 27

Advertising
background image

Crestron TPS-12G/15G/17G-QM Isys

®

G-Series Touchpanels

Identity Code

Net ID

The Net ID of the TPS-12G/15G/17G-QM has been factory set to 03. The Net IDs of
multiple TPS-12G/15G/17G-QM devices in the same system must be unique. The
NET ID is set using the internal setup menu (refer to “Interface Menu” on page 28).
Net ID may also be set from a personal computer (PC) via the Crestron Toolbox™
(refer to “Establishing Communication” which starts on page 56).

When setting the Net ID, consider the following:

• The Net ID of each unit must match an ID code specified in the SIMPL

Windows program.

• Each network device must have a unique Net ID.

For more details, refer to the Crestron Toolbox help file.

IP ID

The IP ID is set within the TPS-12G/15G/17G-QM’s table using Crestron Toolbox.
For information on setting an IP table, refer to the Crestron Toolbox help file. The IP
IDs of multiple TPS-12G/15G/17G-QM devices in the same system must be unique.

When setting the IP ID, consider the following:

• The IP ID of each unit must match an IP ID specified in the SIMPL

Windows program.

• Each device using IP to communicate with a control system must have a

unique IP ID.

Configuring the Touchpanel

NOTE: The only connection required to configure the touchpanel is power (supplied
via Cresnet). Refer to “Hardware Hookup” which starts on page 45 for details.

To configure the unit it may be necessary to access a series of setup screens prior to
viewing run-time screens that are loaded into the touchpanel for normal operation.
The MAIN MENU for configuring the touchpanel appears when a finger is held to
the touchscreen as power is applied or after the hardware reset button is pressed and
released. Remove your finger when the message "SETUP MODE" briefly appears on
the touchscreen.

Upon entering SETUP MODE the MAIN MENU, as shown in the following
illustration, displays four buttons: Touch Screen Calibration, Exit and Run
Program
, Setup and Diagnostics.

The Exit and Run Program button verifies that all of the setup information has
been saved to the EEPROM and displays the main page that has been programmed
into your system. The remaining buttons on the MAIN MENU open other menus
which are discussed in subsequent paragraphs.

Operations Guide – DOC. 6415B

Isys

®

G-Series Touchpanels: TPS-12G/15G/17G-QM

23

Advertising
This manual is related to the following products: