1. Specifications

1.1 CMA-180/CMA-180T

Metric

Equivalent

WATER CONSUMPTION

PER RACK

.96 G/1.24 G

(3.6 L/4.65 L)

PER HOUR

52 G/74.4 G

(197 L/281L)

OPERATING CYCLE

WASH TIME-SEC

RINSE TIME-SEC

TOTAL CYCLE-SEC

49/44

12/11

61 / 55

49/44

12/11

61/ 55

OPERATING CAPACITY

RACKS PER HOUR (NSF rated)

WASH TANK CAPACITY

PUMP CAPACITY

60

8 GAL.

68 GPM

60

(30.3 L)

(257 LPM)

WATER REQUIREMENTS

WITHOUT BOOSTER HEATER

180°F

(82°C)

WITH BOOSTER HEATER

140°F

(60°C)

WATER INLET

¾”

1.9cm

DRAIN CONNECTION

2”

5.1cm

RINSE PRESSURE SET

20 PSI

±5 PSI

1.41 kg/cm

2

CYCLE TEMPERATURES

WASH-°F

RINSE-°F

155°F-160°F

180°F-195°F

(68°C/71°C)

(82°C/90°C)

DIMENSIONS

DEPTH

25”

(63.5cm)

WIDTH

25 ½”

(65cm)

HEIGHT

59”-60”

(150-152cm)

STANDARD TABLE HEIGHT

34”

(86.3cm)

MAX CLEARANCE FOR DISHES

17 ½”

(44cm)

DRAIN CONNECTION (OFF FLOOR)

11 ½“ – 12½“ (29-32cm)