Run your dispenser wires through the conduit to the control box.

iii.

Run your probe wires to the control box.

iv.

With the machine’s power “OFF”, connect your detergent and rinse dispenser

wires to the red and blue terminals of the power block supplied inside the control
box. The table that follows lists the function of each conductor of the multi-
conductor electrical cable.

Wire Colors

Circuit Voltage

Function

Gray/Violet

200 VAC-249 VAC 50/60 Hz

Main AC Power

Brown

200 VAC-249 VAC 50/60 Hz

Main AC Power

Black

No Connection. Insulate this wire!

This wire is LIVE!

Yellow

24 VAC-240 VAC 50/60 Hz

Detergent Signal

White/Yellow

24 VAC-240 VAC 50/60 Hz

Detergent Signal

Violet

24 VAC-240 VAC 50/60 Hz

Rinse Signal

White/Violet

24 VAC-240 VAC 50/60 Hz

Rinse Signal

The individual conductors need to be connected as shown on the wire
diagram below. Probe wires are to be striped, crimped on barrel male and
female connectors provided, and connected to the pre-wired violet wires in
the control box.

MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.05