15

Presario 1600XL Series

Model 1600T, 1600-XL140, 1600-XL141, 1600-XL142, 1600-XL143, 1600-XL144,

1600-XL146, 1600-XL147, 1600-XL150 XL156, XL157, XL255, XL256, XL257, and XL258

*ECC = Error Correction Code

Hard Drive Test Error Codes

Error Code

Description

Recommended Action

1701-xx

Hard drive format test failed

1. Run the Configuration and Diagnostics

Utilities and verify drive type.

2. Verify that all secondary drives have

secondary drive capability.

3. Replace the hard drive and retest.
4. Replace the system board and retest.

1702-xx

Hard drive read test failed

1703-xx

Hard drive write/read/compare

test failed

1704-xx

Hard drive random seek test

failed

1705-xx

Hard drive controller test failed

1706-xx

Hard drive ready test failed

1707-xx

Hard drive recalibration test

failed

1708-xx

Hard drive format bad track test

failed

1709-xx

Hard drive reset controller test

failed

1710-xx

Hard drive park head test failed

1715-xx

Hard drive head select test failed

1716-xx

Hard drive conditional format

test failed

1717-xx

Hard drive ECC* test failed

1719-xx

Hard drive power mode test

failed

1724-xx

Network preparation test failed

1736-xx

Drive monitoring test failed