Installation Step 6

Install the Premium Control Console

Locate the door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from all moving parts of the
door and door hardware.

The door control is typically attached directly to the
wall. If installing into drywall, drill 5/32" holes and

use the anchors provided. For pre-wired installations
(as in new home construction), Console models
may be mounted to a standard single gang box
(Figure 2).

1. Strip 1/4“ of insulation from one end of the bell

wire and connect it to the two screw terminals on
the back of the door control: white to 2, and
white/red to 1.

2. Pry off cover along one side with a screwdriver

blade (see Figure 1), Fasten with 6ABx1-1/4" self­

tapping screws (standard installation) or 6-32x1"

machine screws (pre-wired installation) as follows:

• Install bottom screw, allowing 1/8" to protrude

above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing. Do not overtighten.

• Insert top tabs and snap on cover.

3. (For standard installation) Run the bell wire up the

wall and across the ceiling to the opener. Use
insulated staples to secure the wire in several
places. Be careful not to pierce the wire with a
staple, creating a short.

4. Connect the bell wire to the terminal screws on

the opener panel: white to 2; white/red to 1.

5. Position the antenna wire as shown.

2-Conductor

Bell Wire

Do

not connect to live electrical wiring. Connect

only to 24 Volt low voltage wires. Connection to
live wires or higher voltage may cause serious
Injury from shock, burn or electrocution.

Children operating or playing with a garage
door opener can injure themselves or others.

The garage door could close and cause

serious injury or death.

Install the door control (or any additional push
buttons) out of the reach of children and away
from ail moving parts of the door and door
hardware,

but where the garage door is visible.

Do not allow children to operate the push
button(s) or the remote control(s).

A moving garage door could injure someone

under it.

Activate the opener only when the

door is properly adjusted, you can see it
clearly, and there are no obstructions to door
travel.

Hardware Shown Actual Size

8

|||Я||||||Ц|||||[ТПТП>

6AB X 1-1/4" Screw

Control Console (std Installation)

та

Insulated

Staples

8

6-32 X 1 ' Screw

Control Console (pre-wired)

Dry Wall Anchors

Figure 1

Figure 2

REMOVE & REPLACE COVER

To Replace,

Insert

Top Tabs

First '

'

Opener

Terminal ScrewsVj

Iri)

Mounting

Hole

j^ermlnal

^Screws

Bottom

Mounting

■ Hole

BACK VIEW

PREMIUM CONTROL CONSOLE

Antenna